Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
BMC Med ; 22(1): 175, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659016

RESUMO

Hybrid closed-loop (HCL) systems seamlessly interface continuous glucose monitoring (CGM) with insulin pumps, employing specialised algorithms and user-initiated automated insulin delivery. This study aimed to assess the efficacy of HCLs at 12 months post-initiation on glycated haemoglobin (HbA1c), time-in-range (TIR), hypoglycaemia frequency, and quality of life measures among children and young people (CYP) with type 1 diabetes mellitus (T1DM) and their caregivers in a real-world setting. Conducted between August 1, 2021, and December 10, 2022, the prospective recruitment took place in eight paediatric diabetes centres across England under the National Health Service England's (NHSE) HCL pilot real-world study. A cohort of 251 CYP (58% males, mean age 12.3 years) with T1DM participated (89% white, 3% Asian, 4% black, 3% mixed ethnicity, and 1% other). The study utilised three HCL systems: (1) Tandem Control-IQ AP system, which uses the Tandem t:slim X2 insulin pump (Tandem Diabetes Care, San Diego, CA, USA) with the Dexcom G6® CGM (Dexcom, San Diego, CA, USA) sensor; (2) Medtronic MiniMed™ 780G with the Guardian 4 sensor (Medtronic, Northridge, CA, USA); and (3) the CamAPS FX (CamDiab, Cambridge, UK) with the Ypsomed insulin pump (Ypsomed Ltd, Escrick, UK) and Dexcom G6® CGM.All systems were fully funded by the NHS. Results demonstrated significant improvements in HbA1c (average reduction at 12 months 7 mmol/mol; P < 0.001), time-in-range (TIR) (average increase 13.4%; P < 0.001), hypoglycaemia frequency (50% reduction), hypoglycaemia fear, and quality of sleep (P < 0.001) among CYP over a 12-month period of HCL usage. Additionally, parents and carers experienced improvements in hypoglycaemia fear and quality of sleep after 6 and 12 months of use. In addition to the improvements in glycaemic management, these findings underscore the positive impact of HCL systems on both the well-being of CYP with T1DM and the individuals caring for them.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Insulina , Qualidade de Vida , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Masculino , Criança , Adolescente , Feminino , Glicemia/efeitos dos fármacos , Insulina/administração & dosagem , Insulina/uso terapêutico , Inglaterra , Automonitorização da Glicemia/métodos , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Estudos Prospectivos , Hipoglicemia , Controle Glicêmico/métodos
2.
Diabetes Technol Ther ; 26(3): 198-202, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38444312

RESUMO

The presence of diabetic ketoacidosis (DKA) at diagnosis of type 1 diabetes (T1D) is associated with higher glycated hemoglobin levels over time. We evaluated whether hybrid-closed loop (HCL) therapy from onset of T1D could prevent the adverse impact of DKA at diagnosis on long-term glycemic outcomes. This was a posthoc analysis from 51 adolescents using HCL from diagnosis of T1D as part of the CLOuD trial (NCT02871089). We compared glycemic and insulin metrics between adolescents with (n = 17) and without (n = 34) DKA at diagnosis. Participants with and without DKA at diagnosis had similar time in target glucose range 3.9-10.0 mmol/L (70-180 mg/dL), time below range (<3.9 mmol/L, <70 mg/dL) and HbA1c at 6, 12, and 24 months. While insulin requirements at 6 months were higher in those with DKA at diagnosis, this was not statistically significant after adjusting for bodyweight. Residual C-peptide secretion was similar between groups. We conclude that HCL therapy may mitigate against the negative glycemic effects of DKA at T1D diagnosis.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Humanos , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/etiologia , Glicemia , Sistemas de Infusão de Insulina , Insulina Regular Humana
3.
J Diabetes Sci Technol ; : 19322968241231950, 2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38494876

RESUMO

BACKGROUND/OBJECTIVE: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). METHODS: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. RESULTS: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). CONCLUSIONS: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).

6.
Diabetes Technol Ther ; 25(7): 485-491, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37229591

RESUMO

Objective: We aimed to assess whether percentage of time spent in hypoglycemia during closed-loop insulin delivery differs by age group and time of day. Methods: We retrospectively analyzed data from hybrid closed-loop studies involving young children (2-7 years), children and adolescents (8-18 years), adults (19-59 years), and older adults (≥60 years) with type 1 diabetes. Main outcome was time spent in hypoglycemia <3.9 mmol/L (<70 mg/dL). Eight weeks of data for 88 participants were analyzed. Results: Median time spent in hypoglycemia over the 24-h period was highest in children and adolescents (4.4% [interquartile range 2.4-5.0]) and very young children (4.0% [3.4-5.2]), followed by adults (2.7% [1.7-4.0]), and older adults (1.8% [1.2-2.2]); P < 0.001 for difference between age groups. Time spent in hypoglycemia during nighttime (midnight-05:59) was lower than during daytime (06:00-23:59) across all age groups. Conclusion: Time in hypoglycemia was highest in the pediatric age group during closed-loop insulin delivery. Hypoglycemia burden was lowest overnight across all age groups.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adolescente , Idoso , Criança , Pré-Escolar , Humanos , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem , Adulto , Pessoa de Meia-Idade
7.
Diabet Med ; 40(2): e15015, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36424877

RESUMO

AIMS: Hybrid closed-loop (HCL) systems are characterised by integrating continuous glucose monitoring (CGM) with insulin pumps that automate insulin delivery via specific algorithms and user-initiated insulin delivery. The aim of the study was to evaluate effectiveness of HCLs on HbA1c, time-in-range (TIR), hypoglycaemia frequency and quality of life measures in children and young people (CYP) with T1D, and their carers. METHODS: Patients were recruited prospectively into the National Health Service (NHS) England real-world HCL observational study from the 1st of August 2021 to the 10th of December 2022 from eight paediatric diabetes centres in England. RESULTS: There were 251 CYP (147 males, 58%) with T1DM recruited with a mean age at recruitment of 12.3 (SD 3.5) (range 2-19) years. Eighty nine per cent of the CYP were of white ethnicity, 3% Asian, 4% black and 3% mixed ethnicity, and 1% were recorded as others. The HCL systems used in the study were: (1) Tandem Control-IQ AP system, which uses the Tandem t:slim X2 insulin pump (Tandem Diabetes Care, San Diego, CA) with the Dexcom G6® CGM (Dexcom, San Diego, CA) sensor; (2) Medtronic MiniMed™ 780G (Medtronic, Northridge, CA) and (3) CamAPS FX (CamDiab, Cambridge, UK.) All systems were fully funded by the national health service. CONCLUSIONS: The results of the NHS England Closed Loop Study in Children and Young People showed improvements in glycaemic control, TIR, frequency of hypoglycaemia, hypoglycaemia fear and quality of sleep for children and young people when using HCL for 6 months. Hypoglycaemia fear and quality of sleep were also improved for their parents and carers at 6 months.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Masculino , Humanos , Criança , Adolescente , Pré-Escolar , Adulto Jovem , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Medicina Estatal , Glicemia , Qualidade de Vida , Automonitorização da Glicemia/métodos , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Insulina/uso terapêutico , Inglaterra/epidemiologia , Sistemas de Infusão de Insulina , Hipoglicemiantes/uso terapêutico
8.
J Diabetes Sci Technol ; : 19322968221141924, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36475908

RESUMO

OBJECTIVE: Many hybrid closed-loop (HCL) systems struggle to manage unusually high glucose levels as experienced with intercurrent illness or pre-menstrually. Manual correction boluses may be needed, increasing hypoglycemia risk with overcorrection. The Cambridge HCL system includes a user-initiated algorithm intensification mode ("Boost"), activation of which increases automated insulin delivery by approximately 35%, while remaining glucose-responsive. In this analysis, we assessed the safety of "Boost" mode. METHODS: We retrospectively analyzed data from closed-loop studies involving young children (1-7 years, n = 24), children and adolescents (10-17 years, n = 19), adults (≥24 years, n = 13), and older adults (≥60 years, n = 20) with type 1 diabetes. Outcomes were calculated per participant for days with ≥30 minutes of "Boost" use versus days with no "Boost" use. Participants with <10 "Boost" days were excluded. The main outcome was time spent in hypoglycemia <70 and <54 mg/dL. RESULTS: Eight weeks of data for 76 participants were analyzed. There was no difference in time spent <70 and <54 mg/dL between "Boost" days and "non-Boost" days; mean difference: -0.10% (95% confidence interval [CI] -0.28 to 0.07; P = .249) time <70 mg/dL, and 0.03 (-0.04 to 0.09; P = .416) time < 54 mg/dL. Time in significant hyperglycemia >300 mg/dL was 1.39 percentage points (1.01 to 1.77; P < .001) higher on "Boost" days, with higher mean glucose and lower time in target range (P < .001). CONCLUSIONS: Use of an algorithm intensification mode in HCL therapy is safe across all age groups with type 1 diabetes. The higher time in hyperglycemia observed on "Boost" days suggests that users are more likely to use algorithm intensification on days with extreme hyperglycemic excursions.

9.
J Diabetes Sci Technol ; : 19322968221145184, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36540007

RESUMO

BACKGROUND: CamAPS FX is a hybrid closed-loop smartphone app used to manage type one diabetes. The closed-loop algorithm has a default target glucose of 5.8 mmol/L (104.5 mg/dL), but users can select personal glucose targets (adjustable between 4.4 mmol/L and 11.0 mmol/L [79 mg/dL and 198 mg/dL, respectively]). METHOD: In this post-hoc analysis, we evaluated the impact of personal glucose targets on glycemic control using data from participants in five randomized controlled trials. RESULTS: Personal glucose targets were widely used, with 20.3% of all days in the data set having a target outside the default target bin (5.5-6.0 mmol/L [99-108 mg/dL]). Personal glucose targets >6.5 mmol/L (117 mg/dL) were associated with significantly less time in target range (3.9-10.0 mmol/L [70-180 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: mean difference = -3.2 percentage points [95% CI: -5.3 to -1.2; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -10.8 percentage points [95% CI: -14.1 to -7.6; P < .001]). Personal targets >6.5 mmol/L (117 mg/dL) were associated with significantly lower time (<3.9 mmol/L [<70 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: -1.85 percentage points [95% CI: -2.37 to -1.34; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -2.68 percentage points [95% CI: -3.49 to -1.86; P < .001]). CONCLUSIONS: Discrete study populations showed differences in glucose control when applying similar personal targets.

10.
N Engl J Med ; 387(10): 882-893, 2022 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-36069870

RESUMO

BACKGROUND: Whether improved glucose control with hybrid closed-loop therapy can preserve C-peptide secretion as compared with standard insulin therapy in persons with new-onset type 1 diabetes is unclear. METHODS: In a multicenter, open-label, parallel-group, randomized trial, we assigned youths 10.0 to 16.9 years of age within 21 days after a diagnosis of type 1 diabetes to receive hybrid closed-loop therapy or standard insulin therapy (control) for 24 months. The primary end point was the area under the curve (AUC) for the plasma C-peptide level (after a mixed-meal tolerance test) at 12 months after diagnosis. The analysis was performed on an intention-to-treat basis. RESULTS: A total of 97 participants (mean [±SD] age, 12±2 years) underwent randomization: 51 were assigned to receive closed-loop therapy and 46 to receive control therapy. The AUC for the C-peptide level at 12 months (primary end point) did not differ significantly between the two groups (geometric mean, 0.35 pmol per milliliter [interquartile range, 0.16 to 0.49] with closed-loop therapy and 0.46 pmol per milliliter [interquartile range, 0.22 to 0.69] with control therapy; mean adjusted difference, -0.06 pmol per milliliter [95% confidence interval {CI}, -0.14 to 0.03]). There was not a substantial between-group difference in the AUC for the C-peptide level at 24 months (geometric mean, 0.18 pmol per milliliter [interquartile range, 0.06 to 0.22] with closed-loop therapy and 0.24 pmol per milliliter [interquartile range, 0.05 to 0.30] with control therapy; mean adjusted difference, -0.04 pmol per milliliter [95% CI, -0.14 to 0.06]). The arithmetic mean glycated hemoglobin level was lower in the closed-loop group than in the control group by 4 mmol per mole (0.4 percentage points; 95% CI, 0 to 8 mmol per mole [0.0 to 0.7 percentage points]) at 12 months and by 11 mmol per mole (1.0 percentage points; 95% CI, 7 to 15 mmol per mole [0.5 to 1.5 percentage points]) at 24 months. Five cases of severe hypoglycemia occurred in the closed-loop group (in 3 participants), and one occurred in the control group; one case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In youths with new-onset type 1 diabetes, intensive glucose control for 24 months did not appear to prevent the decline in residual C-peptide secretion. (Funded by the National Institute for Health and Care Research and others; CLOuD ClinicalTrials.gov number, NCT02871089.).


Assuntos
Peptídeo C , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Insulina , Adolescente , Glicemia/análise , Peptídeo C/metabolismo , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/metabolismo , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
11.
Diabetes Obes Metab ; 24(12): 2309-2318, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35837984

RESUMO

AIM: To examine changes in the lived experience of type 1 diabetes after use of hybrid closed loop (CL), including the CamAPS FX CL system. MATERIALS AND METHODS: The primary study was conducted as an open-label, single-period, randomized, parallel design contrasting CL versus insulin pump (with or without continuous glucose monitoring). Participants were asked to complete patient-reported outcomes before starting CL and 3 and 6 months later. Surveys assessed diabetes distress, hypoglycaemia concerns and quality of life. Qualitative focus group data were collected at the completion of the study. RESULTS: In this sample of 98 youth (age range 6-18, mean age 12.7 ± 2.8 years) and their parents, CL use was not associated with psychosocial benefits overall. However, the subgroup (n = 12) using the CamAPS FX system showed modest improvements in quality of life and parent distress, reinforced by both survey (p < .05) and focus group responses. There were no negative effects of CL use reported by study participants. CONCLUSIONS: Closed loop use via the CamAPS FX system was associated with modest improvements in aspects of the lived experience of managing type 1 diabetes in youth and their families. Further refinements of the system may optimize the user experience.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Insulina/uso terapêutico , Qualidade de Vida , Hipoglicemiantes/uso terapêutico , Glicemia , Resultado do Tratamento , Sistemas de Infusão de Insulina , Pais/psicologia
12.
Lancet Digit Health ; 4(4): e245-e255, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35272971

RESUMO

BACKGROUND: Closed-loop insulin delivery systems have the potential to address suboptimal glucose control in children and adolescents with type 1 diabetes. We compared safety and efficacy of the Cambridge hybrid closed-loop algorithm with usual care over 6 months in this population. METHODS: In a multicentre, multinational, parallel randomised controlled trial, participants aged 6-18 years using insulin pump therapy were recruited at seven UK and five US paediatric diabetes centres. Key inclusion criteria were diagnosis of type 1 diabetes for at least 12 months, insulin pump therapy for at least 3 months, and screening HbA1c levels between 53 and 86 mmol/mol (7·0-10·0%). Using block randomisation and central randomisation software, we randomly assigned participants to either closed-loop insulin delivery (closed-loop group) or to usual care with insulin pump therapy (control group) for 6 months. Randomisation was stratified at each centre by local baseline HbA1c. The Cambridge closed-loop algorithm running on a smartphone was used with either (1) a modified Medtronic 640G pump, Medtronic Guardian 3 sensor, and Medtronic prototype phone enclosure (FlorenceM configuration), or (2) a Sooil Dana RS pump and Dexcom G6 sensor (CamAPS FX configuration). The primary endpoint was change in HbA1c at 6 months combining data from both configurations. The primary analysis was done in all randomised patients (intention to treat). Trial registration ClinicalTrials.gov, NCT02925299. FINDINGS: Of 147 people initially screened, 133 participants (mean age 13·0 years [SD 2·8]; 57% female, 43% male) were randomly assigned to either the closed-loop group (n=65) or the control group (n=68). Mean baseline HbA1c was 8·2% (SD 0·7) in the closed-loop group and 8·3% (0·7) in the control group. At 6 months, HbA1c was lower in the closed-loop group than in the control group (between-group difference -3·5 mmol/mol (95% CI -6·5 to -0·5 [-0·32 percentage points, -0·59 to -0·04]; p=0·023). Closed-loop usage was low with FlorenceM due to failing phone enclosures (median 40% [IQR 26-53]), but consistently high with CamAPS FX (93% [88-96]), impacting efficacy. A total of 155 adverse events occurred after randomisation (67 in the closed-loop group, 88 in the control group), including seven severe hypoglycaemia events (four in the closed-loop group, three in the control group), two diabetic ketoacidosis events (both in the closed-loop group), and two non-treatment-related serious adverse events. There were 23 reportable hyperglycaemia events (11 in the closed-loop group, 12 in the control group), which did not meet criteria for diabetic ketoacidosis. INTERPRETATION: The Cambridge hybrid closed-loop algorithm had an acceptable safety profile, and improved glycaemic control in children and adolescents with type 1 diabetes. To ensure optimal efficacy of the closed-loop system, usage needs to be consistently high, as demonstrated with CamAPS FX. FUNDING: National Institute of Diabetes and Digestive and Kidney Diseases.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Algoritmos , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/induzido quimicamente , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Masculino
13.
J Diabetes Sci Technol ; 15(5): 1042-1051, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34261348

RESUMO

BACKGROUND: Closed-loop technology may help address health disparities experienced by adolescents, who are more likely to have suboptimal glycemic control than other age groups and, because of their age, find diabetes self-management particularly challenging. The CamAPS FX closed-loop has sought to address accessibility and usability issues reported by users of previous prototype systems. It comprises small components and a smartphone app used to: announce meal-time boluses, adjust ("boost" or "ease-off") closed-loop insulin delivery, customize alarms, and review/share data. We explored how using the CamAPS FX platform influences adolescents' self-management practices and everyday lives. METHODS: Eighteen adolescents were interviewed after having ≥6 months experience using the closed-loop platform. Data were analyzed thematically. RESULTS: Participants reported feeling less burdened and shackled by diabetes because closed-loop components were easier to carry/wear, finger-pricks were not required, the smartphone app provided a discreet and less stigmatizing way of managing diabetes in public, and they were able to customize alarms. Participants also reported checking and reviewing data more regularly, because they did so when using the smartphone for other reasons. Some reported challenges in school settings where use of personal phones was restricted. Participants highlighted how self-management practices were improved because they could easily review glucose data and adjust closed-loop insulin delivery using the "boost" and "ease-off" functions. Some described how using the system resulted in them forgetting about diabetes and neglecting certain tasks. CONCLUSIONS: A closed-loop system with small components and control algorithm on a smartphone app can enhance usability and acceptability for adolescents and may help address the health-related disparities experienced by this age group. However, challenges can arise from using a medical app on a device which doubles as a smartphone. TRIAL REGISTRATION: Closed Loop From Onset in Type 1 Diabetes (CLOuD); NCT02871089; https://clinicaltrials.gov/ct2/show/NCT02871089.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Algoritmos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Smartphone
15.
Diabetes Technol Ther ; 23(7): 500-507, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33605790

RESUMO

Objective: To understand and explore data sharing practices among adolescents and their parents using a closed-loop system. Methods: Eighteen adolescents (aged 11-18 years) and 19 parents were interviewed after adolescents had ∼6 months experience of using a closed-loop system, which permitted them to share glucose and insulin data with parents/caregivers. Data were analyzed thematically. Results: There was considerable variability in how parent-child dyads perceived, valued, and undertook data sharing. Parents of early adolescents (11-13 years) reported making extensive use of "real time" data to remotely manage their child's diabetes and early adolescents described needing and wanting this input. Parents of middle adolescents (14-16 years) described making greater use of retrospective data. To avoid conflict and encourage and support their son/daughter's autonomy, these individuals reported practicing watchful waiting and only intervening after concerns about a pattern of problematic behavior or their child's safety arose. Middle adolescents indicated that data sharing had been done primarily for the benefit of their parents, although they also noted quality of life benefits for themselves. Among late adolescents (17+ years), parents were simply remote because their son/daughter had not permitted access to their data. Participants recommended clear ground rules be put in place about when, and how, data sharing should be used. Conclusions: To help parent-child dyads use data sharing in ways which minimize conflict and optimize constructive parental support, we recommend tailored input and support, which takes account of family dynamics, the young person's developmental maturity, and the different ways in which data are used across the adolescent age range.


Assuntos
Pais , Qualidade de Vida , Adolescente , Criança , Humanos , Disseminação de Informação , Pesquisa Qualitativa , Estudos Retrospectivos
16.
BMJ Open ; 10(3): e033500, 2020 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-32169925

RESUMO

INTRODUCTION: Management of newly diagnosed type 1 diabetes (T1D) in children and adolescents is challenging for patients, families and healthcare professionals. The objective of this study is to determine whether continued intensive metabolic control using hybrid closed-loop (CL) insulin delivery following diagnosis of T1D can preserve C-peptide secretion, a marker of residual beta-cell function, compared with standard multiple daily injections (MDI) therapy. METHODS AND ANALYSIS: The study adopts an open-label, multicentre, randomised, parallel design, and aims to randomise 96 participants aged 10-16.9 years, recruited within 21 days of diagnosis with T1D. Following a baseline mixed meal tolerance test (MMTT), participants will be randomised to receive 24 months treatment with conventional MDI therapy or with CL insulin delivery. A further 24-month optional extension phase will be offered to all participants to continue with the allocated treatment. The primary outcome is the between group difference in area under the stimulated C-peptide curve (AUC) of the MMTT at 12 months post diagnosis. Analyses will be conducted on an intention-to-treat basis. Key secondary outcomes are between group differences in time spent in target glucose range (3.9-10 mmol/L), glycated haemoglobin (HbA1c) and time spent in hypoglycaemia (<3.9 mmol/L) at 12 months. Secondary efficacy outcomes include between group differences in stimulated C-peptide AUC at 24 months, time spent in target glucose range, glucose variability, hypoglycaemia and hyperglycaemia as recorded by periodically applied masked continuous glucose monitoring devices, total, basal and bolus insulin dose, and change in body weight. Cognitive, emotional and behavioural characteristics of participants and parents will be evaluated, and a cost-utility analysis performed to support adoption of CL as a standard treatment modality following diagnosis of T1D. ETHICS AND DISSEMINATION: Ethics approval has been obtained from Cambridge East Research Ethics Committee. The results will be disseminated by peer-reviewed publications and conference presentations. TRIAL REGISTRATION NUMBER: NCT02871089; Pre-results.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemiantes/uso terapêutico , Células Secretoras de Insulina/fisiologia , Insulina/uso terapêutico , Adolescente , Automonitorização da Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Células Secretoras de Insulina/efeitos dos fármacos , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
17.
Diabetes Technol Ther ; 22(6): 468-475, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32048877

RESUMO

Background: We explored health professionals' views about the training, support, and resourcing needed to support people using closed-loop technology in routine clinical care to help inform the development of formal guidance. Methods: Interviews were conducted with health professionals (n = 22) delivering the Closed Loop from Onset in Type 1 Diabetes (CLOuD) trial after they had ≥6 months' experience of supporting participants using a closed-loop system. Data were analyzed descriptively. Results: Interviewees described how, compared with other insulin regimens, teaching and supporting individuals to use a closed-loop system could be initially more time-consuming. However, they also noted that after an initial adjustment period, users had less need for initiating contact with the clinical team compared with people using pumps or multiple daily injections. Interviewees highlighted how a lessened need for ad hoc clinical input could result in new challenges; specifically, they had fewer opportunities to reinforce users' diabetes knowledge and skills and detect potential psychosocial problems. They also observed heightened anxiety among some parents due to the constant availability of data and unrealistic expectations about the system's capabilities. Interviewees noted that all local diabetes teams should be empowered to deliver closed-loop system care, but stressed that health professionals supporting closed-loop users in routine care will need comprehensive technology training and standardized clinical guidance. Conclusion: These findings constitute an important starting point for the development of formal guidance to support the rollout of closed-loop technology. Our recommendations, if actioned, will help limit the potential additional burden of introducing closed-loop systems in routine clinical care and help inform appropriate user education and support.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Pessoal de Saúde/educação , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Automonitorização da Glicemia , Humanos , Pesquisa Qualitativa
18.
BMC Res Notes ; 10(1): 465, 2017 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-28882195

RESUMO

BACKGROUND AND AIMS: The relationship between vitamin D deficiency and type I DM is an ongoing area of interest. The study aims to identify the prevalence of vitamin D deficiency in children and adolescents with T1DM and to assess the impact of treatment of vitamin D deficiency on their glycaemic control. METHODS: Retrospective data was collected from 271 children and adolescents with T1DM. The vitamin D deficient (25(OH)D <30 nmol/L) and insufficient (25(OH)D 30-50 nmol/L) patients were treated with 6000 units of cholecalciferol and 400 units of cholecalciferol, once daily for 3 months respectively. HbA1c and 25(OH)D concentrations were measured before and at the end of the vitamin D treatment. RESULTS: 14.8% from the whole cohort (n = 271) were vitamin D deficient and 31% were insufficient. Among the children included in the final analysis (n = 73), the mean age and plasma 25(OH)D concentration (±SD) were 7.7 years (±4.4) and 32.2 nmol/l (±8.2) respectively. The mean 25(OH)D concentration post-treatment was 65.3 nmol/l (±9.3). The mean HbA1c (±SD) before and after cholecalciferol was 73.5 mmol/mol (±14.9) and 65 mmol/mol (±11.2) respectively (p < 0.001). Children with higher pre-treatment HbA1c had greater reduction in HbA1c (p < 0.001) and those with lower 25(OH)D concentration showed higher reduction in HbA1c (p = 0.004) after treatment. CONCLUSIONS: Low 25(OH)D concentrations are fairly prevalent in children and adolescents with T1DM, treatment of which, can potentially improve the glycaemic control.


Assuntos
Colecalciferol/farmacologia , Diabetes Mellitus Tipo 1/sangue , Deficiência de Vitamina D/sangue , Deficiência de Vitamina D/tratamento farmacológico , Criança , Pré-Escolar , Colecalciferol/administração & dosagem , Comorbidade , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Feminino , Hemoglobinas Glicadas , Humanos , Masculino , Prevalência , Estudos Retrospectivos , Resultado do Tratamento , Deficiência de Vitamina D/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...